User’s Manual—SNAP™ 600 Printer
4. Instructions for Factory / Field Installation of Top
Reflective Sensor 590013(F)
Installation Procedure
1. Disconnect Power to Printer.
2. Disconnect Stacker Interface Cable & Remote Display Panel (if so
equipped).
3. Remove the Rear Cover (save screws).
4. Remove ¼-20 Phillips Head Screw located on the back of the Upright
Frame closest to the Supply Unwind & just above the smaller Power
Supply
5. Remove the Turn Bar from the Web Guide Bracket & replace with the Bar
supplied with the kit as shown in Figure 1.
991374
PHILLIPS PAN HEAD SCREW
584024
SHAFT, WEB GUIDE (SENSOR)
581128
SENSOR
989975
4-40 X 3/16 PAN HEAD SCREW
Figure 1
6. Hold the Bar with the through hole in a vertical position. Reassemble
Step 4. ¼-20 Screw & secure. Be sure Web Guide Slides smoothly on Bar.
7. Assemble Harnessed Sensor into the through hole front the top & secure
with the 4-40 Screw in the inside hole in the Turn Bar. See Figure 1.
8. Insert the Connector / Lead through the Upright Frame behind the Web
Guide Knob and connect to connector marked “Top Reflective Sensor” in
MCB Board.
9. Reinstall Cover from Step 3.